Industrial filtration solutions

Industrial filters is a collective term for filter solutions used in the manufacturing and process industries to purify air, gases and process streams of particles and other contaminants. The aim is to improve air quality, protect equipment, maintain process stability and comply with purification and emissions requirements.

AAF/Dinair offers dust separation, flue gas cleaning and wet filtration of process fluids, as well as solutions for high temperatures and gaseous contaminants. We can also help you select the right materials and tailor the solution to your process, operating conditions and installation.

The choice depends on the contaminants that need to be filtered out – whether these are air, gases or liquids – and on the prevailing operating conditions. Particle size and temperature also influence the choice of the most suitable solution.

  • Dust and solid particles: Existing dust collection systems utilise, amongst other things, industrial filter hoses, filter bags, cartridges and cassettes. Industrial filter cartridges can provide a large filter surface area in a small space, whilst filter hoses offer greater flexibility in terms of design. The choice is also influenced by the properties of the dust and the operating conditions of the system.
  • Complete dust collection: Choose an industrial dust collector when you need a complete system to capture dust from production. Depending on the process, bag filters, cartridge filters or wet gas scrubbers may be used.
  • Flue gases: In flue gas cleaning, dust and other contaminants are separated from gases, for example those resulting from the combustion of biofuel or waste. The equipment is selected based on the temperature, humidity and chemical composition of the gases.
  • Particles in liquids: Opt for wet (liquid) filtration when solids need to be removed from a process liquid. The solution is tailored to the liquid, the particle size and the desired degree of purity.
  • Very high temperatures: Opt for high-temperature filters when standard materials cannot withstand the temperature in the process.
  • Odours and gaseous substances: Choose gas filters and AMC filters when the contaminants consist of gases, odours or chemical substances that are not captured by standard particle filters. The range includes, amongst other things, molecular filters, combination filters, cassettes, cylinders and filter media.
  • Very high clean air requirements: EPA, HEPA and ULPA filters are used when very small particles need to be removed from the air, for example in the pharmaceutical industry, the healthcare sector and the electronics industry. Solutions are available to meet various purity requirements.

You can find more products and solutions in our range for industrial and process filtration.

In which sectors are industrial filters used?

Industrial filtration is used in sectors including metalworking, grain and animal feed, cement and minerals, asphalt production, and pulp and paper.

During welding, cutting and grinding, fumes and dust can be captured using extraction and dust separation systems. In the grain and animal feed sector, filter hoses or cartridges can separate dust from dry raw materials. During crushing and transport in the cement and minerals industries, hose filters and cartridge filters, amongst others, are used to capture dust.

In asphalt production, hot, dust-laden gases must be purified using materials that can withstand high temperatures. In the pulp and paper industry, dust and fly ash can be treated using dust separation, whilst gaseous pollutants may require other purification steps.

What affects performance?

Performance is primarily influenced by the size and properties of the contaminants, the material’s ability to capture them, and the volume of the stream to be purified. Small particles may require a higher degree of purification, whilst large quantities of dust require sufficient surface area and effective cleaning.

Density also affects the result. Damaged filter elements or leaky connections can allow contaminants to pass through, even if the material has the correct degree of filtration.

Which filter classes and standards are used?

In general ventilation, ISO 16890 is used, with the groups ePM1, ePM2.5, ePM10 and ISO Coarse. The classification indicates how effectively particles in different size classes are captured.

For high-efficiency particulate air (HEPA) filters, EN 1822 is used, which classifies EPA, HEPA and ULPA filters based on their separation efficiency.

In industrial dust separation and flue gas filtration, there is no single filter class suitable for all processes. Instead, the properties of the contaminants, the operating conditions and the emission requirements of the installation determine which filters and materials can be used.

How is the filter adapted to the installation?

At Dinair, we begin by reviewing your process: what needs to be filtered, what the flow rate is and in what environment the filter must operate. This information helps us to select the filter type, material and dimensions that are suitable for the installation.

For dust separation, we also examine the properties of the dust. Abrasive dust can wear down the filter material, whilst sticky dust can become trapped and make cleaning more difficult. If the dust is flammable, the risk of explosion must be assessed as part of the system’s design.

Materials for flue gas cleaning

In flue gas cleaning, the filter material must both capture dust and withstand the environment within the installation. At Dinair, we help you select the material based on the temperature, humidity and chemical composition of the flue gases. We offer, amongst other things:

  • PTFE: A material with high resistance to many chemicals. It can be used where both heat and chemically demanding flue gases place high demands on the filter.
  • PPS: A material used in certain flue gas processes, for example for the separation of fly ash. To assess its suitability, we must take into account both the temperature and the composition of the gases.
  • Aramid: A heat-resistant material that may be suitable for hot and relatively dry processes. Moisture and chemicals must be assessed, as these can affect its service life.
  • P84: A heat-resistant synthetic fibre whose structure provides a large surface area for capturing fine dust particles.
  • Glass fibre: A material used for dust separation at high temperatures. Here too, the filter design must be adapted to the process and the plant’s cleaning system.

Sizing and filter area

Once we have reviewed the choice of materials, we will assist you in sizing the solution. This involves adapting the size and design of the filter to the volume of air or gas to be purified, the dust load and the available space within the plant.

For filter hoses and filter cartridges, the total filter area required to handle the flow rate and dust load is calculated. An insufficient filter area can lead to high pressure drop, i.e. significant resistance when the air flows through the filter. The positioning of the filter elements and the method used to remove dust from them also influence performance. When replacing filters in an existing system, we also ensure that the dimensions and fixings are compatible with the equipment.

Background information for an enquiry

To help you choose the right solution, we need the following:

  • The process involved and the contaminants that need to be filtered out.
  • The flow rate, temperature and humidity conditions the filter must be able to withstand.
  • What your requirements are regarding purification or emissions.

For an existing installation, the model, filter dimensions and current filter material are also useful details. Please do let us know if you are experiencing issues such as high pressure drop, frequent filter replacements or leaks. You do not need to have all the details ready before contacting us – we will go through the circumstances with you.

How do air and gas filters affect energy consumption?

When filtering air and gas, energy consumption is affected by the filter’s pressure drop. This is the resistance that arises when the air flow passes through the filter. A higher pressure drop means that the fan must consume more energy to maintain the same flow rate.

When particles accumulate in the filter, the pressure drop usually increases. If the fan cannot compensate for the higher resistance, the air or gas flow may actually decrease.

Sufficient filter surface area, the correct material and monitoring the pressure drop during operation will help you minimise unnecessary energy consumption. Cleaning washable filters and replacing worn filter elements also help the system to maintain its capacity. When making your choice, you should therefore take into account the purchase cost, energy consumption, maintenance and expected service life.

Get in touch

AAF/Dinair can assist you with industrial filters for air, gases and process fluids – from material selection and sizing to the maintenance of existing filter systems. For dust and flue gases, we also offer bespoke products manufactured in Sweden.

We can assist you with filter replacements, inspections, maintenance, repairs, installations, leak detection, filter analyses and emission measurements.

Please contact us via the contact form for advice on new filters or improvements to your existing system.

Frequently asked questions

Yes. A treatment plant can be designed with multiple treatment stages to remove different contaminants. For example, dust can be captured in an initial stage, whilst gaseous substances can be treated in a different stage. The combination required depends on the contaminants present in the effluent and the treatment requirements of the plant.

Dry filtration refers to the removal of particles from air or gas. The gas may contain a certain amount of moisture, but is still classified as dry filtration. Wet filtration refers to the removal of particles from liquids.

A filter element, such as a filter hose or filter cartridge, captures dust in a filter-based dust separator. Such a system also contains other components for separating and processing the dust. Other types, such as cyclones or gas scrubbers, separate the particles without a filter element.

Yes. Filters that have been in use can be analysed to assess their condition, identify any problems and serve as a basis for selecting materials for future filter replacements.

The replacement interval depends on the type of filter, the level of contamination, the operating time and the rate at which the pressure drop changes. Regular checks will indicate when the capacity begins to decline and a replacement needs to be scheduled.

Products
Document Finder
Sustainability
Contacts
Mail
Top of Page